DPA 60 & 120 – 208V UL – MODULAR UPS


ABB DPA 60 & 120 – 208V UL – MODULAR UPS
Decentralized Parallel Architecture (DPA)
DPA 60 and 120 - The modular UPS for small and medium-sized data centers
Suit applications requiring N+1 redundancy and flexibility
The DPA 60 and 120 are 208V modular UPSs based on 20kW modules and are available in two cabinet configurations:
- DPA 60 cabinet is 20–60kW with internal batteries
- DPA 120 cabinet is 20–120kW with external battery cabinets
Today’s data centers require continuous uptime, especially the smaller but rapidly growing edge data centers. That high reliability target is why ABB’s DPA 60 and 120 are based on Decentralized Parallel Architecture (DPA). Only a truly redundant architecture like DPA with no single point of failure allows modules to be swapped out while the system is running in double conversion.
Each high-reliability, standardized module is self-contained and can be swapped at any time, so nothing will ever need to be switched off – making routine maintenance safe, fast and easy.
The DPA 60 and 120 are designed to secure continuity of critical operations for small to mid-sized data centers, server rooms and other IT applications. It also protects industrial automation processes, healthcare facilities and many other vertical markets where operations are of a critical nature.



DPA 60
- 60kW or 40kW N+1 redundant power. In one UPS cabinet.
- 300kW power in one system. By paralleling up to five cabinets.
- 20kW power in one UPS module. Truly scalable power – featuring DPA.
94% double conversion efficiency, 99% eco-mode efficiency reduced power losses.
< 10min service time. Low MTTR to exchange one UPS module.

DPA 120
- 120kW or 100kW N+1 redundant power. In one UPS cabinet.
- 600kW power in one system. By paralleling up to five cabinets.
- 20kW power in one UPS module. Truly scalable power – featuring DPA.
94% double conversion efficiency, 99% eco-mode efficiency reduced power losses.
< 10min service time. Low MTTR to exchange one UPS module.
Total vertical and horizontal scalability
DPA 60
DPA 120

- One to three UPS modules
- DPA display in each module
- Connectivity
- Battery circuit breakers
- Decentralized output switches
- Internal maintenance bypass switch (optional)
- Sistem display

- One to six UPS modules
- DPA display in each module
- Connectivity
- Battery circuit breakers
- Decentralized output switches
- Internal maintenance bypass switch (optional)
- System display
True parallel architecture
Basic system configuration - module includes:
- 20kW rectifier and inverters
- Decentralized static bypass switch
- True online double conversion UPS
- Built-in modular isolation
- Built-in backfeed protection
- Individual module display
- HMI interface with mimic diagram and LCD providing information in five languages
The lowest total cost of ownership
The cabinet includes:
- Optimized cabinets, with either 60kW or 120kW of rated power
- Bottom cable entry (standard) and top cable entry (optional)
- Rectifier, bypass terminals (single or dual-input mains connection available) and UPS output terminals
- Battery breakers and output switches for each module set. DPA 60 (standard); DPA 120 (optional)
- Graphical color touch screen system display
- Communication interfaces: RS-232 and USB ports, I/O dry contacts (e.g. EPO, GEN On) and external bypass interlock
Options
- Internal battery options for optimized 60kW cabinet
- Matching external battery cabinets
- Maintenance bypass cabinet (matching or wall mount)
- Battery monitoring
- Control and monitoring (Modbus RS-485, Modbus TCP/IP, SNMP, Bacnet and others)
- Seismic bracing